Description
Standard Parameter: Standard SpO2, Pulse Rate, Plath bar & SpO2 Waveform, Rechargeable Lithium Battery, Battery Charging Seat Optional: NIBP Function and Accessories, TEMP Function and Accessories● Ergonomic design for point of care
● Suitable for adult, pediatric and neonatal patients
● High resolution 3.5." color LCD display
● Classic SpO2/TEMP/NIBP measurement availble
● Upto 15 hours long battery life with recharge seat

| Standard SpO2 | |
| Accuracy | 70% to 100%: ±2%, unspecified 0% to 69%: |
| Patients Range | 0-100% |
| Alarm Range | Same as display range, alarm limit setup length is 1% |
| PR | |
| Range | 20bpm ~ 254bpm |
| Alarm Range | Same as display range, alarm limit setup length is 1bpm |
| Refreshing Rate | About 1 second |
| Accuracy | ±3 bpm |
| PR Average | 8 second |
| Pitch Tone | Yes |
| TEMP | |
| Accuracy | ±0.2°C (0°C ~ 50℃) |
| Range | 0℃ ~ 50℃ |
| Alarm Range | Upper limit 0.1℃ ~ 50.0℃, Lower limit 0.0℃~ 49.9℃ |
| Unit | ℃ or °F |
| Alarm Delay Time | <10s |
| Mechanica | |
| Size | 175 mm (h) x 85 mm (w) x32 mm (d) |
| Weight | Single SpO2 version 280g, SpO2+NIBP+TEMP version 370g |
| Battery | |
| Input Power | 100-240 VAC,0.4A,50/60Hz,±10% |
| Type | Lithium ion |
| Capacity | 3.7V/4000mAh |
| Working Time | Brand new battery with fully charged ≥ 15 hours |
| Charging Time | Around 8 hours |
| I /O | |
| Display | 3.5" LCD 480*320 pixels |
| Buttons | 3 shortcut keys, 5 function keys |
| Charging interface | |
| USB | |
| Environmental Specification | |
| Temperature | 0℃~ 40℃ |
| Humidity | 15% ~ 80%, Non - Condensing |
| Patients Range | Neonatal, Pediatric, Adult |
| NIBP | |
| Method of Measurement | Oscillation |
| The Measured Parameters | SBP, DBP, MAP |
| Unit | mmHg or kPa |
| Operating Mode | Manual, automatic, continuous |
| SBP Range | Adult(30 mmHg ~ 270mmHg) , Child(30 mmHg ~ 230mmHg) |
| DBP Range | Adult(10 mmHg ~ 220mmHg) , Child(10 mmHg ~ 165mmHg) |
| MAP Range | Adult(10 mmHg ~ 240mmHg) , Child(10 mmHg ~ 175mmHg) |
| Accuracy | ±5mmHg or ±4%, whichever is the greater |
| Range | Same as display range, alarm limit setup length is 1mmHg |
| Alarm Delay Time | <10s |
| Cuff Pressure Range | 0 mmHg ~ 300 mmHg |
| Cuff Inflation Speed | Cuff Inflation Speed ≤50mmHg/s |
| Static Pressure Measurement Error | ±3mmHg (not up to over pressure protection) |
| Display Resolution | 1mmHg |
| Standard Parameter | Standard SpO2, Pulse Rate, Plath bar & SpO2 Waveform, Rechargeable Lithium Battery, Battery Charging Seat |
| Optional | NIBP Function and Accessories, TEMP Function and Accessories |
● Power adapter
● Data cable: It is used to connect the monitor with a computer or other devices for data transmission
● Protective case, cleaning cloth, user manual (which may include a quick start guide), warranty card, certificate of conformity, etc.