Description
The infusion pump is suitable for pet medical institutions for intravenous infusion of pets, can manually control the infusion speed and preset total amount and other parameters, so as to be able to accurately control the output of drugs. At the same time, it has constant speed infusion, fast infusion, KVO function, real-time display and alarm function, which is more convenient for operators to use.• Audible Alarms:Automatic infusion,sound alarm,AC and DC dual-use.
• Quick release function:Quickrelease function,power-on self-test.
• Multiple infusion modes:Infusion modes:ml/hour,drops/minute,time mode.
• Flow rate accuracy calibration:Forgetalarm function,flow rate accuracy calibration.
• Totalization display,totalization reset:With totalization display and totalization reset function.
• Pharmacy FunctionsMemoryfunction,libraryfunction,Chinese/English switching.
• Display,volume settable:Real-time time display and setting,adjustable keytone setting,adjustable brightness of backlight display,alarm volume can be set and adjusted.
Infusion Mode: | Velocity mode,drop mode,time mode |
Flow rate range: | 1ml/h~1200ml/h,step0.ml/h |
Dropping rate range: | 1drop/min~400 drops/min,step1drop/min |
Preset volume range: | 0.1ml~9999.9ml |
Time range: | 1second~99 hours59 minutes 59 seconds |
KVO speed: | 1ml/h~5ml/h |
Quick-discharge speed: | 10ml/h~1200ml/h |
BOLUS speed: | 10ml/h~1200ml/h |
Pressure units: | KPa,mmHg,bar |
Infusion quantity precision error: | ±5%(after calibration) |
Volume: | Button volume,alarm volume adjustable in three steps |
Pressure detection: | Detection range OKPa~130KPa,blocking pressure three adjustable gears |
Bubble detection: | detection range 20ul~200ul,bubble size adjustable in three steps |
Display: | 3.0-inch white dot-matrix screen,backlight brightness adjustable in three steps |
Auto-restart: | automatic infusion when the blockage is lifted |
Self-test function: | power-on self-test,real-time self-test duringoperation. |
Forgetting operation time: | 30 seconds~3minutes adjustable |
Language: | support for Chinese,English display |
History Record: | 1000 recentalarmsand infusion records,viewat anytime |
AC power supply: | AC100V~240V.50HZ/60HZ |
Internal Battery: | DC11.1V,2000mAh,can last more than 8 hours when using 25mL/h infusion. |
Operating environment: | Temperature+5℃~+40℃,Humidity 30%~80%,Atmospheric pressure 86kPa~106kPa |
Storage environment: | temperature-20°℃~55℃,humidity 10%~93%,atmospheric pressure 50kPa~106kPa |
Safety Class: | Classland internally powered devices,Type BF,IPX2 |
Product size: | Approx.151*181.5*205mm (LxWxH) |
Product weight: | 1.5kg |
• Power adapter
• Infusion set accessories: They may include infusion tube clamps, fixing devices, etc., which are used to connect the infusion set to the infusion pump and ensure stability and safety during the infusion process.
• User Manual: It provides information such as the usage method, operation guide, and precautions of the infusion pump to help users operate the equipment correctly and safely.
• Warranty card: It is used to prove the warranty period and scope of the product, and it is an important proof for users to seek after-sales service when the equipment has problems.