Infusion Pump for Vet Use

Model:HF-710C

Description

Veterinary infusion pump is with the classic vertical design. The software compensation error is within±5% after calibration. Adjustable level setting and occlusion pressure release function is make it commonly acceptable by the veterinary hospital. Double CPU and numeric keypad make it safe and more user friendly.
Features
Specifications
Package
Features

• 10 levels setting for occlusion and air bubble volume

• 3000mAh battery and backup time more than 10hrs.

• Big Screen and numeric keypad

• Occlusion pressure release and restarting function

• Infusion Mode:Volume mode, time mode


Technical Specifications
ItemSpecification
Infusion ModeVolume Mode,Time Mode,Drug Mode
Rate Unitml/h,volume/time,d/min
IV SetsStandard single use IV sets(10,15,20,60d/mL,with diameter 3.4~4.5mm)
Flow Rate1.0ml/h~1200ml/h
Increment1.0-99.9ml/h in 0.1ml/h step 100-1200ml/in 1ml/h step
DeviationFlow Rate:≤5%(after calibration)
VTBI0.1~9999.9ml
Total Volume0.0~9999.9 ml
Time1min~99h00min
Purge Rate600ml/h,display purge volume
KVO1.0ml/h~5.0ml/h,adjustable
KeypadNumeric keypad
BOLUSBolus function available,flow rate adjustable
Night ModeScreen to be dim automatically in 5mins after standby time expired.
Occlusion pressure detectorOcclusion pressure detection,40KPa~130KPa,10 levels adjustable with dynamic pressure value display
Occlusion pressure release functionAvailable


ItemSpecification
Air Bubble DetectorUltrasonic detection,≥50ul,Single bubble volume:50~300μl,10 levels adjustable.
Volume8 levels adjustable
Motor Anti-reverse FunctionAnti-reverse function and real-time monitoring
IV Set ManagementOpen system,accept different IVbrands after calibrationcalibration
Self-TestingSelf-Testing before startup and during infusion
Audio Visual Alarm MessageAir bubble,occlusion,door open,infusion finish,standby time expired,battery low,battery empty,battery disengaged,AC Power disengaged,motor error,pump error,air sensor error,parametererror,system error,IV not calibrated
Screen3.2inch brightness LCD
Power SupplyAC Power:100V~240V,50Hz/60Hz,≤25VA
BatteryRechargeable Lithium battery,DC11.1V,3000mAh;operating time:≥10h @25ml/h,displaying remaining battery
Operation ConditionTemperature:+5℃~+40℃,Humidity:20%~90%,Air pressure:70~106KPa
Transport &StorageTemperature:-20℃~+55℃,Humidity:10%~95%,Air pressure:70~106KPa
ClassificationType CF,Class I,IPX3
Dimension145mm×150mm×200mm;Weight:1.7kg


Package includes

● Infusion pipeline: Use disposable infusion sets that meet the standards. The diameter and other specifications of the infusion set should be compatible with the infusion pump, such as compatible infusion sets with a diameter of 3.4-4.5 millimeters.

● Power adapte,Data cable: It is used to connect the infusion pump to the computer or other devices for data transmission

● Depending on the specific model and application of the infusion pump, other accessories will also be provided, such as the instruction manual, warranty card, certificate of conformity, etc.


Need Help Finding a Professional?
We specialize in developing positive, professional relationships with every one of our clients.