Veterinary Anesthesia Machine

Model:SA-10A Vet

Description

Veterinary Anesthesia Machine is a medical device used for animal surgery and diagnosis and treatment. Its main function is to provide anesthetic gas and oxygen for animals to maintain their painless state during the surgery.
Features
Specifications
Package
Features

● Suitable for anesthesia of cats/dogs/monkeys/pigs and other animals under 100KG

● Operation Mode: Semi-closed,open breathing circuit for option

● Flow Range: 0-4L/min

● APL: 0.2-7.0Kpa

● O2 Flush: 25-75L/min high oxygen flow


Technical Specifications
Physical Specifications
Dimensions and Weight(Including   trolley,evaporator,excluding   accessories   package)
Weight≤29kg
Height1193mm
Width480mm
Depth634mm
Castor4 castors and 2 with brakes
Top Shelf
Length425mm
Width274mm
Weight limit10kg
Pneumatic System Specifications
Pipeline  Supply
Gas TypeOxygen
Gas Supply Pressure Range280kPa~600kPa(40psi~87psi)
Input ConnectorNIST or DISS
Gas Supply Pressure Gauge RangeOkPa~1000kPa(Opsi~140psi)
Oxygen  Flush
Flow Range                                                25L/Min~75L/Min
Flowmeter
Range0L/min~5L/min
Accuracy<1L/min:±0.1L/min

1L/min~5L/min:10%of thedisplayed value
Auxiliary  Common  Gas  Outlet(ACGO)
Type                                                             Mechanical switch
Environment Specifications
Operation
Temperature0℃~40℃
Relative humidity(noncondensing)15%~95%
Barometric pressure70kPa~106kPa
Storage
Temperature-20℃~55℃
Relative humidity(noncondensing)10%~9 5%
Barometric pressure50kPa~106kPa


Anesthetic Vaporizer Specifications
Vaporizer
Filling MethodsPour  Fill(Isoflurane 、Sevoflurane、Enflurane)
Weight8.0kg(empty) 、8.5kg(full)
Filling Volume360ml(dry  wick)
300ml(moist   wick)
260ml(between the minimum and maximum
Concentration Rangemarks)0~6%(Isoflurane,Enflurane) 0~8%(Sevoflurane)
Concentration  Accuracy Range
-20%~+30%of  the  set  value  or  -5%~+7.5%
of the max value,whichever is the greater      
Vaporizer BaseSingle  position,Selectatec  connecting type
Anesthetic Gas Scavenging System Specifications
Active AGSS
Size500mmx150mm   x120mm
Pump Rate
80L/min
Passive AGSS
Connector30mm OD conical
Anesthetic Breathing System Specifications
Breathing System Specifications
System leakage                             ≤100mL/min(under     3kPa)
Connector
Manual Bag Port22mm OD/15mm ID conical
Inhalation22mm OD/15mm ID conical
ExhalationExhalation22mm OD/15mm ID conical
CO2 Absorbent
Volume500mL
APL Valve
RangeOcmH₂O~50cmH₂O
Airway Pressure Gauge
TypeMechanical
Range-20cmH₂O~100cmH₂O
Accuracy±3%


Package includes

● Gas filter tank: It is used to filter impurities in the anesthetic gas to ensure the purity of the anesthetic gas delivered to animals.

● Gas recovery device: It is used to recover the unused anesthetic gas during the surgical process, reducing waste and environmental pollution.

● Induction box: It is used to induce anesthesia in animals before surgery, enabling them to smoothly enter the anesthetized state.

● Fixed bracket: It is used to fix various components of the anesthesia machine, such as the evaporator, induction box, gas recovery device, etc., to ensure the stability of the anesthesia machine during use.

● Other accessories: such as oxygen cylinders (or air pumps), masks, tracheal intubation tubes, etc. These accessories may vary depending on the specific model and application of the anesthesia machine.

● User Manual: Provides information such as usage instructions, operation guides, and maintenance for the anesthesia machine. The user manual is an important reference for users to understand and use the anesthesia machine.


Need Help Finding a Professional?
We specialize in developing positive, professional relationships with every one of our clients.
Get in touch →