Description
Blood and Infusion Warmer is to warm the blood or fluid and to relieve the patient's hyperthermia;it is widely used beforeoperation,during operation and after operation and ICU,NICU,Pediatric Dept.,Emergency Dept.,and Outpatient Dept.forheating blood or infusion.Small design,direct display andsimple operation makes it user friendly.● Exquisite workmanship,small design,0.2kgweight,more installation way optional
● Multiple Temperature Control Protection Technology
● Hardware and software temperature control protection to ensure the effective and safe heating
● 2mins Fast Heating
● Fast heating to transfer the heat to the patient
● Three Heating Groove
● Long,middle,short groove to meet differentneeds
● High Accuracy
● Deviation is within±1℃

| Item | Specification |
| Temperature Setting | ℃:35.0℃~42.0℃ F:95.0°F~107.6°F |
| Temperature Accuracy | ℃:≤土1℃ F:≤土1.8°F |
| Increment | ℃:0.1℃ °F:0.2°F |
| Optional Unit | ℃、F |
| Warming Up Time | ≤2min |
| Overheat Protection | 46℃,hardware and software protection |
| Alarm | Overheat,low temperature,system error,door open,warming upalarm. |
| Blood and IV Sets | Standard single used PVC blood or IV tubes(diameter:3.4-4.5mm) |
| Display | LED |
| Heating Way | Long,Middle,short grooves |
| Item | Specification |
| Installation Way | IV Knob,Hanger optional |
| Power Supply | Input:100-240V(AC Power),50/60HZ,0.3-0.7A Output:12V(DC Power)2.5A |
| Power Consumption | 85VA |
| Operation Environment | Temp.:+5°℃-+30℃;Relative Humidity: 20%-80%;Atmosphere:76.0kPa-106.0kPa |
| Transportation and Storage Environment | Temp.:-20℃-+55°℃;Relative Humidity: 10%-93%;Atmosphere:50.0kPa-106.0kPa |
| Degree of Protection against Ingress of Liquids | IPX1 |
| Degree of Protection against Electric Shock | ClassII,Type CF |
| Working Mode | Continuous heating |
| Dimension | 180×70×35mm |
| Weight Net Weight | 0.2kg;With Knob:0.4kg |
● Detachable power cord
● Hanging sling or fixing device: It is used to fix the main unit in a suitable position, such as an infusion stand or beside a hospital bed, for easy use.
● Fixing clamp or fastening device: It is used to fix the blood transfusion/infusion tubing on the heater to ensure that the tubing does not move or fall off during the heating process.
● User Manual: Provides information such as product usage instructions, operation guides, maintenance and care. The user manual is an important reference for users to understand and use the product.
● Other accessories: Depending on the specific model and application of the product, the package may also include other accessories such as temperature sensors, heating tubes, spare power cords, etc.